ABSOLUTE MAXIMUM RATINGS (1)
PARAMETER
TEST CONDITION
SYMBOL
VALUE
UNIT
INPUT
Reverse voltage
Forward current
Forward surge current
Power dissipation
Junction temperature
OUTPUT
tp ≤ 10 µs
VR
5
V
IF
60
mA
IFSM
3
A
Pdiss
100
mW
Tj
125
°C
Collector emitter voltage
Emitter collector voltage
Collector current
Collector peak current
Power dissipation
Junction temperature
COUPLER
tp/T = 0.5, tp ≤ 10 ms
VCEO
32
V
VECO
7
V
IC
50
mA
ICM
100
mA
Pdiss
150
mW
Tj
125
°C
Isolation test voltage (RMS)
Total power dissipation
Ambient temperature range
Storage temperature range
Soldering temperature (2)
2 mm from case, t ≤ 10 s
VISO
Ptot
Tamb
Tstg
Tsld
3750
250
- 55 to + 100
- 55 to + 125
260
VRMS
mW
°C
°C
°C
Notes
(1) Tamb = 25 °C, unless otherwise specified.
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not
implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum
ratings for extended periods of the time can adversely affect reliability.
(2) Refer to wave profile for soldering conditions for through hole devices.
ELECTRICAL CHARACTERISTCS
PARAMETER
INPUT
Forward voltage
Junction capacitance
OUTPUT
Collector emitter voltage
Emitter collector voltage
Collector emitter cut-off current
COUPLER
AC isolation test voltage (RMS)
Collector emitter saturation voltage
Cut-off frequency
Coupling capacitance
TEST CONDITION
IF = 50 mA
VR = 0 V, f = 1 MHz
IC = 1 mA
IE = 100 µA
VCE = 10 V, IF = 0
f = 50 Hz, t = 1 s
IF = 10 mA, IC = 1 mA
VCE = 5 V, IF = 10 mA,
RL = 100 Ω
f = 1 MHz
SYMBOL
VF
Cj
VCEO
VECO
ICEO
VISO
VCEsat
fc
Ck
MIN.
32
7
3750
TYP.
1.25
50
10
110
0.3
MAX.
1.6
100
0.3
UNIT
V
pF
V
V
nA
VRMS
V
kHz
pF
Note
Tamb = 25 °C, unless otherwise specified.
Minimum and maximum values were tested requierements. Typical values are characteristics of the device and are the result of engineering
evaluations. Typical values are for information only and are not part of the testing requirements.
www.vishay.com
230
For technical questions, contact: optocoupler.answers@vishay.com
Document Number: 83886
Rev. 1.4, 08-May-08