HCTFCP Datasheet, PDF (1/5 Pages) Vishay Siliconix – Suitable for insert assembly systems
www.vishay.com
HCTF CP Series
Vishay Beyschlag
High Current Thermal Fuse
The HCTF CP series is especially designed for high current
applications with an operating temperature up to 160 °C. In
case of excess heat in the range of the functioning
temperature of (235 ± 15) °C the thermo fuse opens
automatically and disconnects the circuit. Typical
applications are automotive power electronics that are
connected to steady battery power (B+ or terminal
number 30).
FEATURES
• Functioning temperature: F = (235 ± 15) °C
• Holding temperature: H = 160 °C
• Current:  50 A
• Suitable for insert assembly systems
• Material categorization: For definitions of compliance
please see www.vishay.com/doc?99912
APPLICATIONS
• Automotive
- Fan control units
- ABS
- Diesel glow plug relays
- Diesel pre-heaters
- Electric coolant pumps
TECHNICAL SPECIFICATIONS
DESCRIPTION
Functioning temperature F
Holding temperature H (1000 h)
Voltage UDC
Current IDC (1)
Cold resistance Rcold
Residual resistance Rs
Note
(1) Current rating depends on external thermal management.
DIMENSIONS
HCTF 235 CP
(235 ± 15) °C
160 °C
24 V
 50 A
 0.1 m
> 1 M
W1
W2
D1
D2
DIMENSIONS - Mass and relevant physical dimensions
TYPE
W1
(mm)
W2
(mm)
HCTF CP
26 ± 0.5
6.5 ± 0.5
Note
(2) Between sleek surfaces
D1 (2)
(mm)
7.7 ± 0.3
D2
(mm)
1.8 ± 0.2
MASS
(g)
1.45 ± 0.3
Revision: 10-Apr-13