English
Language : 

10-FZ06NRA075FU-P969F08 Datasheet, PDF (8/9 Pages) Vincotech – neutral point clamped inverter
10-FZ06NRA045FH-P965F
preliminary datasheet
flowNPC 0
NPC Application
600V/30A
Figure 27.
Typical efficiency as a function of output power
η=f(Pout)
100,0
per MODULE
99,5
φ=0º
99,0
98,5
98,0
φ=180º
97,5
97,0
96,5
96,0
0
2
4
6
8
10
12
P out (kVA)
Conditions:
Tj= 125 °C
fsw=
20
kHz
DC link= 700 V
parameter:
phase displacement
φ
from
0°
in steps of 30 °
to 180 °
Figure 29.
Typical available output power as a function of
heat sink temperature
Pout=f(Th)
12
per MODULE
Figure 28.
Typical efficiency as a function of output power
η=f(Pout)
100,0
per MODULE
99,5
2kHz
99,0
98,5
128kHz
98,0
97,5
97,0
96,5
96,0
0
2
4
6
8
10
12
Pout (kVA)
Conditions:
Tj= 125 °C
DC link= 700 V
parameter:
Switching freq.
fsw from
2
kHz to
in steps of factor 2
φ= 0 °
128 kHz
10
2kHz
128kHz
8
6
4
2
0
60
65
70
75
80
85
90
95
100
T h ( o C)
Conditions:
Tj= Tjmax-25 °C
DC link= 700 V
φ=
0
°
parameter:
Switching freq.
fsw from
2
kHz to
128 kHz
in steps of factor 2
copyright by Vincotech
8
Revision: 2