English
Language : 

10-FZ06NRA075FU-P969F08 Datasheet, PDF (5/9 Pages) Vincotech – neutral point clamped inverter
10-FZ06NRA045FH-P965F
preliminary datasheet
flowNPC 0
NPC Application
600V/30A
Figure 16.
Typical average switching loss as a function of
phase displacement
Ploss=f(φ)
30
25
Boost IGBT
IoutRMS=Imax
20
15
10
5
IoutRMS=6% Imax
0
0
20
40
60
80
100
120
140
160
1φ8(0º ) 200
Figure 17.
Typical average switching loss as a function of
phase displacement
Ploss=f(φ)
18
16
Boost FWD
IoutRMS=Imax
14
12
10
8
6
4
IoutRMS=6% Imax
2
0
0
20
40
60
80
100
120
140
160
φ1(8º 0)
200
Conditions:
parameter:
Tj= 125 °C
DC link=
IoRMS
700
from
V
3A
in steps of 6 A
fsw=
20 kHz
to
42 A
A
Figure 18.
Typical total loss as a function of phase displacement
and IoutRMS
Ploss=f(IoRMS;φ)
Boost IGBT
42
40
37
P loss (W)
34
30-35
31
25-30
28
25
20-25
23
15-20
20
17
10-15
14
5-10
11
8
0-5
6
3
0 15 30 45 60 75 90 105 120 135 150 165 180
φ(º )
Conditions:
parameter:
Tj= 125 °C
DC link=
IoRMS
700
from
V
3A
in steps of
6A
fsw=
20 kHz
to
42 A
A
Figure 19.
Typical total loss as a function of phase displacement
and IoutRMS
Ploss=f(IoRMS;φ)
Boost FWD
42
40
P loss60(-W65)
37
55-60
34
50-55
31
45-50
28
40-45
25
35-40
23
30-35
20
25-30
20-25
17
15-20
14
10-15
11
5-10
8
0-5
6
3
0 15 30 45 60 75 90 105 120 135 150 165 180
φ(º )
Conditions:
Tj= 125 °C
DC link= 700 V
fsw=
20
kHz
Conditions:
Tj= 125 °C
DC link= 700 V
fsw=
20
kHz
copyright by Vincotech
5
Revision: 2