English
Language : 

10-FZ062TA030FB-P983D18 Datasheet, PDF (7/20 Pages) Vincotech – Vincotech clip-in housing
10-FZ062TA030(FB/FB01/FB02/FB03)-P983(D18/D28/D38/D48)
10-F0062TA030(FB/FB03)-P983(D19/D49)
preliminary datasheet
PFC
Figure 5
Typical switching energy losses
as a function of collector current
E = f(ID)
0,8
0,6
0,4
0,2
PFC SWITCH
Eon
Eoff
Eon
Eoff
0,0
0
10
20
30
40
inductive load
Tj =
25/125 °C
VDS =
400
V
VGS =
15
V
Rgon =
4
Ω
Rgoff =
4
Ω
Figure 7
Typical reverse recovery energy loss
as a function of collector (drain) current
Erec = f(Ic)
0,300
0,250
0,200
Tj = Tjmax -25°C
0,150
0,100
0,050
Tj = 25°C
0,000
0
10
20
30
40
inductive load
Tj =
VDS =
25/125 °C
400
V
VGS =
15
V
Rgon =
4
Ω
Rgoff =
4
Ω
50 I C (A) 60
PFC SWITCH
Erec
Erec
50 I C (A) 60
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
0,8
PFC SWITCH
0,6
0,4
Tj = Tjmax -25°C
0,2
Eon
0,0
0
Eoff
2
4
inductive load
Tj =
25/125 °C
VDS =
400
V
VGS =
15
V
ID =
18
A
Tj =25°C
6
Eon
Eoff
8
R G ( Ω ) 10
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
0,160
PFC SWITCH
0,140
0,120
0,100
Tj = Tjmax - 25°C
Erec
0,080
0,060
0,040
0,020
Tj = 25°C
Erec
0,000
0
2
4
6
8 R G ( Ω ) 10
inductive load
Tj =
VDS =
25/125 °C
400
V
VGS =
15
V
ID =
18
A
Copyright by Vincotech
7
Revision: 3