English
Language : 

V23990-P631-A-P1-14 Datasheet, PDF (6/18 Pages) Vincotech – Output inverter IGBT
flow 90PIM 1 600V/6A
V23990-P631-A-PM
preliminary data sheet
V23990-P631-A-02-14
Output inverter
Figure 5.
Typical switching energy losses
as a function of collector current
Output inverter IGBT
E = f (Ic)
0,4
Figure 6.
Typical switching energy losses
as a function of gate resistor
Output inverter IGBT
E = f (RG)
0,4
Eon
0,3
0,3
Eoff
Eon
0,2
0,2
Eoff
Erec
0,1
0,1
Erec
0
0
2
4
6
8
10 I C (A) 12
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Rgon= 64 ȍ
Rgoff= 32 ȍ
0
0
60
120
180
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Ic = 6 A
240 R G ( : ) 300
Figure 7.
Typical switching times as a
function of collector current
Output inverter IGBT
t = f (Ic)
1
0,1
tdon
0,01
tr
tdoff
tf
Figure 8.
Typical switching times as a
function of gate resistor
Output inverter IGBT
t = f (RG)
1
tdoff
0,1
tf
tdon
tr
0,01
0,001
0
2
4
6
8
10 IC (A) 12
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Rgon= 64 ȍ
Rgoff= 32 ȍ
0,001
0
60
120
180
inductive load, Tj = 125 °C
VCE = 300 V
VGE= 15 V
Ic = 6 A
240 R G ( : ) 300
Ccooppyryigrhitgbhy tTybcoyEVleicntrconoictsech
Finsinger Feld 1, D-85521 Ottobrunn
Revision:1