English
Language : 

10-FZ062PA200SA-P996F08 Datasheet, PDF (6/15 Pages) Vincotech – Trench Fieldstop IGBT technology
Figure 9
Typical switching times as a
function of collector current
t = f(IC)
1
tdon
tf
0,1
tr
0,01
0,001
0
100
200
With an inductive load at
Tj =
150
°C
VCE =
300
V
VGE =
±15
V
Rgon =
2
Ω
Rgoff =
2
Ω
Figure 11
Typical reverse recovery time as a
function of collector current
trr = f(IC)
0,4
0,36
0,32
0,28
0,24
0,2
Tj = Tjmax -25°C
0,16
0,12
0,08
Tj = 25°C
0,04
0
0
100
200
At
Tj =
VCE =
VGE =
Rgon =
25/150 °C
300
V
±15
V
2
Ω
Output Inverter
FZ06 / F0062PA200SA
preliminary datasheet
Output inverter IGBT
tdoff
Figure 10
Typical switching times as a
function of gate resistor
t = f(RG)
10
1
tdoff
0,1
0,01
Output inverter IGBT
tdon
tr
tf
300
I C (A)
400
0,001
0
4
8
With an inductive load at
Tj =
150
°C
VCE =
300
V
VGE =
±15
V
IC =
200
A
12
16 R G ( Ω ) 20
Output inverter FRED
Figure 12
Typical reverse recovery time as a
function of IGBT turn on gate resistor
trr = f(Rgon)
0,6
Output inverter FRED
0,5
trr
0,4
Tj = Tjmax -25°C
0,3
trr
trr
0,2
0,1
trr
Tj = 25°C
300
I C (A)
400
0
0
At
Tj =
VR =
IF =
VGE =
4
8
25/150 °C
300
V
200
A
±15
V
12
16
R g on ( Ω ) 20
Copyright by Vincotech
6
Revision: 1