English
Language : 

10-FZ062PA200SA-P996F08 Datasheet, PDF (13/15 Pages) Vincotech – Trench Fieldstop IGBT technology
FZ06 / F0062PA200SA
preliminary datasheet
Switching Definitions Output Inverter
Figure 9
Output inverter FRED
Turn-on Switching Waveforms & definition of tQrr
(tQrr = integrating time for Qrr)
150
%
Qrr
100
Id
50
tQrr
0
-50
-100
-150
3,1
3,25
3,4
3,55
3,7
3,85
4
time(us)
Id (100%) =
Qrr (100%) =
tQrr =
203
A
16,33
μC
0,55
μs
Figure 10
Output inverter FRED
Turn-on Switching Waveforms & definition of tErec
(tErec= integrating time for Erec)
120
%
Erec
100
80
60
tErec
40
20
Prec
0
-20
3,1
3,25
3,4
3,55
3,7
3,85 time(us) 4
Prec (100%) =
Erec (100%) =
tErec =
60,82
kW
3,89
mJ
0,55
μs
Copyright by Vincotech
13
Revision: 1