English
Language : 

V23990-P825-F-P2-14 Datasheet, PDF (5/16 Pages) Vincotech – Trench Fieldstop IGBT3 Technology
Output Inverter
V23990-P825-F-PM
preliminary datasheet
Figure 5
Typical switching energy losses
as a function of collector current
E = f(Ic)
6
5
4
3
2
1
0
0
40
80
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/150 °C
300
V
±15
V
4
Ω
4
Ω
Output inverter IGBT
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
6
Eoff
5
4
Eoff
Eon
3
Eon:
2
1
0
120
160
I C (A) 200
0
4
8
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/150 °C
300
V
±15
V
100
A
Output inverter IGBT
Eon
Eon
Eoff
Eoff
12
16 R G( Ω ) 20
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(Ic)
3,5
3
2,5
2
1,5
1
0,5
0
0
40
80
120
With an inductive load at
Tj =
25/150 °C
VCE =
300
V
VGE =
±15
V
Rgon =
4
Ω
Output inverter IGBT
Erec
Erec
160 I C (A) 200
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
3,5
3
2,5
2
1,5
1
0,5
0
0
4
8
12
With an inductive load at
Tj =
25/150 °C
VCE =
300
V
VGE =
±15
V
IC =
100
A
Output inverter IGBT
Erec
Erec
16 R G( Ω ) 20
copyright by Vincotech
5
Revision: 2