English
Language : 

V23990-P706-F-D1-14 Datasheet, PDF (5/11 Pages) Vincotech – Maximum Ratings / Höchstzulässige Werte
flow 90PACK 1 600V/ 75A
V23990-P706-F-PM
final data sheet
V23990-P706-F-01-14
Output inverter
Figure 9.
Typical reverse recovery time as a
function of IGBT turn on gate resistor
Output inverter FRED diode
trr = f (Rgon)
Figure 10.
Typical reverse recovery current as a
function of IGBT turn on gate resistor
Output inverter FRED diode
IRRM = f (Rgon)
0,5
120
100
0,4
80
0,3
60
0,2
40
0,1
20
0
0
7
14
21
Tj =
VR =
IF=
VGE=
125 °C
300 V
75 A
±15 V
28 R Gon ( : ) 35
0
0
7
14
21
Tj =
VR =
IF=
VGE=
125 °C
300 V
75 A
±15 V
28 R Gon ( : ) 35
Figure 11. Typical reverse recovery charge as a
function of IGBT turn on gate resistor
Output inverter FRED diode
Qrr = f (Rgon)
7
6
5
4
3
2
1
0
0
7
14
21
Tj =
VR =
IF=
VGE=
125 °C
300 V
75 A
±15 V
28 R Gon ( :) 35
Figure 12.
Typical rate of fall of forward
and reverse recovery current as a
function of IGBT turn on gate resistor
Output inverter FRED diode
dI0/dt,dIrec/dt= f (Rgon)
5000
4000
3000
2000
dIrec/dt
1000
dI0/dt
0
0
7
14
21
28 R Gon ( :) 35
Tj =
VR =
IF=
VGE=
125 °C
300 V
75 A
±15 V
Copyright by Vincotech
5
Revision: 1