English
Language : 

V23990-P705-F-01-14 Datasheet, PDF (5/11 Pages) Vincotech – Maximum Ratings / Höchstzulässige Werte
flow 90PACK 1 600V/ 50A
V23990-P705-F-PM
final data sheet
V23990-P705-F-01-14
Output inverter
Figure 9.
Typical reverse recovery time as a
function of IGBT turn on gate resistor
Output inverter FRED diode
trr = f (Rgon)
Figure 10.
Typical reverse recovery current as a
function of IGBT turn on gate resistor
Output inverter FRED diode
IRRM = f (Rgon)
0,3
120
0,25
100
0,2
80
0,15
60
0,1
40
0,05
20
0
0
8
16
24
Tj =
VR =
IF=
VGE=
125 °C
300 V
50 A
±15 V
32 R Gon ( : ) 40
0
0
8
16
24
Tj =
VR =
IF=
VGE=
125 °C
300 V
50 A
±15 V
32 R Gon ( : ) 40
Figure 11. Typical reverse recovery charge as a
function of IGBT turn on gate resistor
Output inverter FRED diode
Qrr = f (Rgon)
5
Figure 12.
Typical rate of fall of forward
and reverse recovery current as a
function of IGBT turn on gate resistor
Output inverter FRED diode
dI0/dt,dIrec/dt= f (Rgon)
5000
4
4000
3
3000
dI0/dt
2
2000
dIrec/dt
1
1000
0
0
8
16
24
Tj =
VR =
IF=
VGE=
125 °C
300 V
50 A
±15 V
32 R Gon ( :) 40
0
0
8
16
24
32 R Gon ( :) 40
Tj =
VR =
IF=
VGE=
125 °C
300 V
50 A
±15 V
Copyright by Vincotech
5
Revision: 1