English
Language : 

10-FZ122PA050SC01-P997F18 Datasheet, PDF (5/15 Pages) Vincotech – Compact and low inductance design
Output Inverter
FZ12 / F0122PA050SC01
preliminary datasheet
Figure 5
Typical switching energy losses
as a function of collector current
E = f(IC)
9
7,5
Output inverter IGBT
Eon High T
Figure 6
Typical switching energy losses
as a function of gate resistor
E = f(RG)
9
7,5
6
Eoff High T
6
Eoff Low T
4,5
Eon Low T
4,5
3
3
1,5
1,5
0
0
0
20
40
60
80
I C (A) 100
0
8
16
With an inductive load at
Tj =
VCE =
VGE =
Rgon =
Rgoff =
25/150 °C
600
V
±15
V
8
Ω
8
Ω
With an inductive load at
Tj =
VCE =
VGE =
IC =
25/150 °C
600
V
±15
V
50
A
Output inverter IGBT
Eon High T
Eon Low T
Eoff High T
Eoff Low T
24
32 R G ( Ω ) 40
Figure 7
Typical reverse recovery energy loss
as a function of collector current
Erec = f(IC)
5
4
Tj = Tjmax -25°C
3
2
1
Output inverter IGBT
Erec
Figure 8
Typical reverse recovery energy loss
as a function of gate resistor
Erec = f(RG)
5
Tj = Tjmax -25°C
4
3
Tj = 25°C
Erec
2
Tj = 25°C
1
Output inverter IGBT
Erec
Erec
0
0
0
20
40
60
80
I C (A) 100
0
8
16
24
32 R G ( Ω ) 40
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
Rgon =
8
Ω
With an inductive load at
Tj =
25/150 °C
VCE =
600
V
VGE =
±15
V
IC =
50
A
Copyright by Vincotech
5