English
Language : 

V23990-P823-F-P2-19 Datasheet, PDF (3/4 Pages) Vincotech – flowPACK 1 3rd gen
flowPACK 1 3rd gen
Output Inverter Application
V23990-P823-F-PM
preliminary datasheet
600V/50A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
20,0
2kHz
Inverter
18,0
16,0
16kHz
14,0
12,0
10,0
8,0
6,0
4,0
2,0
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi = 0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
2,00 / 1,47
1
999
2
999
4
999
8
999
16
999
3,00 / 2,21
666
666
666
666
666
5,00 / 3,68
399
399
399
399
399
7,50 / 5,52
266
266
266
266
266
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi = 0,8
fsw from 1 kHz to 16kHz in steps of factor 2
Th =
90
°C
Motor eff = 0,85
10,00 / 7,36
200
200
200
200
200
15,00 / 11,03
133
133
133
133
133
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
98,0
97,0
96,0
16kHz
95,0
94,0
93,0
92,0
91,0
90,0
0,0
5,0
10,0
15,0
At
Tj =
150
°C
DC link = 320
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
Inverter
20,0
25,0
Pout (kW)
copyright by Vincotech
3
Revision: 2