English
Language : 

V23990-P823-F-P2-19 Datasheet, PDF (1/4 Pages) Vincotech – flowPACK 1 3rd gen
flowPACK 1 3rd gen
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 8 Ω
Rgoff = 8 Ω
V23990-P823-F-PM
preliminary datasheet
600V/50A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
80
70
Mi*cosfi = 1
IGBT
60
50
40
30
20
10
Mi*cosfi = -1
0
0
10
20
30
40
50
60
70
80
Iout (A)
At
Tj =
150
°C
Mi*cosfi from -1 to 1 in steps of 0,2
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
70
FRED
60
Mi*cosf i= -1
50
40
30
20
10
Mi*cosfi = 1
0
0
10
20
30
40
50
60
70
80
Iout (A)
At
Tj =
150
°C
Mi*cosfi from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
30,0
Ploss = f(Iout)
IGBT
Figure 4
Typical average switching loss
as a function of output current
14,0
Ploss = f(Iout)
FRED
25,0
fsw = 16kHz
20,0
15,0
10,0
5,0
0,0
0
10
20
30
40
50
At
Tj =
150
°C
DC link = 320
V
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
60
70Iout (A) 80
12,0
fsw = 16kHz
10,0
8,0
6,0
4,0
2,0
0,0
0
10
20
30
40
50
At
Tj =
150
°C
DC link = 320
V
fsw from 2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
60
70
80
Iout (A)
copyright by Vincotech
1
Revision: 2