English
Language : 

V23990-P769-A60-D2-19 Datasheet, PDF (3/3 Pages) Vincotech – Typical average static loss as a function of output current
flowPIM 2
Output Inverter Application
V23990-P769-A60-PM
datasheet
1200 V / 75 A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
60,0
Inverter
50,0
2kHz
40,0
30,0
20,0
16kHz
10,0
0,0
60
65
70
75
80
85
90
95Th ( o C) 100
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
15,00 / 11,03 20,00 / 14,71 25,00 / 18,39
1
374
281
225
2
369
277
221
4
342
256
205
8
294
220
176
16
223
167
134
30,00 / 22,07
187
185
171
147
111
40,00 / 29,42
140
138
128
110
0
50,00 / 36,78
112
111
0
0
0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
2kHz
99,0
Inverter
98,0
97,0
96,0
16kHz
95,0
94,0
93,0
92,0
91,0
90,0
0,0
10,0
20,0
30,0
40,0
50,0
At
Tj =
DC link =
Mi =
cos φ=
fsw from
150
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
60P,0out (kW) 70,0
copyright Vincotech
3
23 Dec 2014 / Revision: 2