V23990-P769-A60-D2-19 Datasheet, PDF (2/3 Pages) Vincotech – Typical average static loss as a function of output current
flowPIM 2
Output Inverter Application
V23990-P769-A60-PM
datasheet
1200 V / 75 A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
120
100
Phase
Iout = f(Mi*cos φ)
Th = 60°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
120
Th = 60°C
100
Iout = f(fsw)
Phase
80
80
Th = 100°C
Th = 100°C
60
60
40
40
20
20
0
-1,0
-0,8
-0,6 -0,4
-0,2
0,0
0,2
0,4
0,6
0M,8i*cos
1,0
φ
At
Tj =
DC link =
fsw =
Th from
150
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
100-110
-0,80
90-100
-0,60
80-90
-0,40
70-80
Iout (A)
60-70
-0,20
0,00
50-60
40-50
30-40
20-30
10-20
At
Tj =
150
DC link = 600
Th =
80
0,20
0,40
0,60
0,80
1,00
1
2 fs4w 8 16 32 64
°C
V
°C
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
120
Phase
Th = 60°C
100
80
60
Th = 100°C
40
20
0
1
10
At
Tj =
DC link =
Th from
Mi =
150
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
23 Dec 2014 / Revision: 2