English
Language : 

V23990-P767-A-D2-19 Datasheet, PDF (3/3 Pages) Vincotech – flow PIM 2 3rd
flow PIM 2 3rd
V23990-P767-A-PM
datasheet
Output Inverter Application
1200 V / 35 A
Figure 9
Inverter
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
25,0
2kHz
20,0
15,0
16kHz
10,0
5,0
0,0
60
65
70
75
80
85
90
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 8 kHz to 64 kHz in steps of factor 2
95
Th
( o C)
100
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
550
500
450
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
5,00 / 3,68
7,50 / 5,52 10,00 / 7,36
1
524
349
262
2
524
349
262
4
499
333
250
8
431
287
216
16
326
218
163
15,00 / 11,03
175
175
166
144
0
20,00 / 14,71
131
131
125
0
0
25,00 / 18,39
0
0
0
0
0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,8
fsw from 1 kHz to 16 kHz in 2 steps
Th =
90
°C
Motor eff =0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
2kHz
99,0
Inverter
98,0
16kHz
97,0
96,0
95,0
94,0
0,0
5,0
10,0
15,0
20,0
25,0
At
Tj =
150
°C
DC link = 600
V
Mi =
1
cosfi =
0,80
fsw from 2 kHz to 16 kHz in steps of factor 2
30,0
35,0
Pout (kW)
copyright Vincotech
3
23 Dec. 2014 / Revision 2