English
Language : 

V23990-P767-A-D2-19 Datasheet, PDF (2/3 Pages) Vincotech – flow PIM 2 3rd
flow PIM 2 3rd
V23990-P767-A-PM
datasheet
Output Inverter Application
1200 V / 35 A
Figure 5
Typical available 50Hz output current
as a function Mi*cosfi
60
50
Phase
Iout = f(Mi*cosfi)
Th = 60°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
60
50
Phase
Iout = f(fsw)
Th = 60°C
40
40
Th = 100°C
30
30
Th = 100°C
20
20
10
10
0
-1,0
-0,8
-0,6 -0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cosfi
At
Tj =
150
°C
DC link = 600
V
fsw =
4
kHz
Th from 60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cosfi and switching frequency
Iout = f(fsw, Mi*cosfi)
-1,00
Iout (A)
-0,80
-0,60
45,0-50,0
40,0-45,0
35,0-40,0
30,0-35,0
25,0-30,0
20,0-25,0
15,0-20,0
10,0-15,0
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
1
2
4
At
Tj =
150
°C
DC link = 600,00 V
Th =
90
°C
8 16 32
fsw
(kHz)
1,00
64
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cosfi = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
60
Phase
50
40
Th = 100°C
30
Th = 60°C
20
10
0
1
10
At
Tj =
150
°C
DC link = 600,00 V
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
copyright Vincotech
2
23 Dec. 2014 / Revision 2