English
Language : 

V23990-P635-A-P1-19 Datasheet, PDF (3/3 Pages) Vincotech – IGBT FRED
flow 90PIM 1 600V/30A
V23990-P635-A-PM
preliminary data sheet
V23990-P635-A-02-19
Output inverter application
General conditions3 phase SPWM, Vgeon= 15 V
Vgeoff=
0V
Figure 9. Typical available electric
peak output power as a
function of heatsink temperature
Inverter
Pout=f(Th)
Rgon= 8 ȍ
Rgoff= 4 ȍ
Figure 10. Typical efficiency
as a function of output power
Inverter
efficiency=f(Pout)
12,0
100,0
10,0
99,0
2kHz
8,0
98,0
2kHz
6,0
97,0
16kHz
4,0
96,0
16kHz
2,0
95,0
0,0
60
65
70
75
80
Conditions:
Tj=125°C
DC link=
Modulation index Mi=
cosfi=
Switching freq. fsw from
parameter
in
85
90
95
Th
(
o
100
C)
300 V
1
0,80
2 kHz to
* 2 steps
16 kHz
94,0
0,0
2,0
4,0
6,0
8,0
10,0
12,0
Pout (kW)
Conditions:
Tj=125°C
DC link= 300 V
Modulation index Mi= 1
cosfi= 0,80
Switching freq.
fsw from 2 kHz to
parameter
in * 2 steps
16 kHz
Figure 11. Typical available overload factor
as a function of motor power
and switching frequency
Inverter
Ppeak/Pnom=f(Pnom,fsw)
400
350
300
250
Conditions:
Tj=125°C
DC link= 300 V
Modulation index Mi= 1
cosfi= 0,8
Switching freq.
fsw from 1 kHz to
parameter
in * 2 steps
Heatsink temperature= 80 °C
Motor efficiency= 0,85
16 kHz
200
150 Motor nominal power (HP/kW)
100
1,50 / 1,10
1
583
2
570
4
546
8
502
16
426
2,00 / 1,47
437
428
410
376
319
3,00 / 2,21
291
285
273
251
213
5,00 / 3,68
175
171
164
151
128
7,50 / 5,52
117
114
0
0
cCopoyrpigyhtrbigy ThytcobEylecVtrionniccsotech
Finsinger Feld 1, D-85521 Ottobrunnn
Revision:1