English
Language : 

V23990-P635-A-P1-19 Datasheet, PDF (1/3 Pages) Vincotech – IGBT FRED
flow 90PIM 1 600V/30A
V23990-P635-A-PM
preliminary data sheet
V23990-P635-A-02-19
Output inverter application
General conditions3 phase SPWM, Vgeon= 15 V
Vgeoff=
0V
Figure 1. Typical avarage static loss
as a function of output current
IGBT
Ploss=f(Iout)
Rgon= 8 ȍ
Rgoff= 4 ȍ
Figure 2.
Typical avarage static loss
as a function of output current
FRED
Ploss=f(Iout)
50
45
Mi*cosfi=1
40
35
30
25
20
15
10
5
0
0
5
10 15 20 25
Conditions:
Tj=125°C
Modulation index * cosfi
parameter Mi*cosfi from
in
Mi*cosfi=-1
30 35 40 45 50
Iout (A)
-1,00 to
1,00
0,20 steps
45
40
35
Mi*cosfi=-1
30
25
20
15
10
5
Mi*cosfi=1
0
0
10
20
30
40
50
Iout (A)
Conditions:
Tj=125°C
Modulation index * cosfi
parameter Mi*cosfi from -1,00 to
1,00
in 0,20 steps
Figure 3. Typical avarage switching loss
as a function of output current
IGBT
Ploss=f(Iout)
20,0
18,0
fsw=16kHz
16,0
14,0
12,0
10,0
8,0
6,0
4,0
2,0
0,0
0
5
10 15 20 25
Conditions:
Switching freq.
parameter
Tj=125°C
DC link=
fsw from
in
fsw=2kHz
30
35
40 Io4u5t (A) 50
300 V
2 kHz to
* 2 steps
16 kHz
Figure 4.
Typical avarage switching loss
as a function of output current
FRED
Ploss=f(Iout)
6,0
5,0
fsw=16kHz
4,0
3,0
2,0
1,0
0,0
0
10
Conditions:
Switching freq.
parameter
fsw=2kHz
20
30
40
50
Iout (A)
Tj=125°C
DC link=
fsw from
in
300 V
2 kHz to
* 2 steps
16 kHz
cCopoyprigyhrt ibgyhTtycbo yEleVctirnoncicos tech
Finsinger Feld 1, D-85521 Ottobrunnn
Revision:1