English
Language : 

V23990-P580-X4X-D2-19 Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
flow1
Output Inverter Application
V23990-P580-*4*-PM
1200V/35A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
25,0
Inverter
2kHz
20,0
15,0
10,0
16kHz
5,0
0,0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
DC link =
Mi =
cos φ=
fsw from
151
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
5,00 / 3,68
1
470
2
458
4
434
8
390
16
315
7,50 / 5,52
313
305
289
260
210
10,00 / 7,36
235
229
217
195
158
15,00 / 11,03
157
153
145
130
0
20,00 / 14,71
118
114
0
0
0
25,00 / 18,39
0
0
0
0
0
At
Tj =
151
°C
DC link = 600
V
Mi =
1
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100,0
99,0
2kHz
98,0
97,0
96,0
16kHz
95,0
94,0
93,0
92,0
91,0
90,0
0,0
5,0
10,0
15,0
20,0
25,0
At
Tj =
DC link =
Mi =
cos φ=
fsw from
151
°C
600
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
Inverter
30P,0out (kW) 35,0
copyright Vincotech
3
Revision: 2