English
Language : 

V23990-P580-X4X-D2-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-P580-*4*-PM
flow1
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 16 Ω
Rgoff = 16 Ω
1200V/35A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
120
IGBT
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
70
FWD
100
80
60
40
20
0
0
10
20
30
At
Tj =
151
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
70,0
Mi*cosfi = 1
Mi*cosfi = -1
40
50
60
Iout (A)
Ploss = f(Iout)
IGBT
60
50
40
30
20
10
0
0
10
20
30
At
Tj =
151
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 4
Typical average switching loss
as a function of output current
40,0
Mi*cosf i= -1
Mi*cosfi = 1
40
50
60
Iout (A)
Ploss = f(Iout)
FWD
60,0
fsw = 16kHz
50,0
40,0
30,0
20,0
10,0
0,0
0
At
Tj =
DC link =
fsw from
fsw = 2kHz
10
20
30
40
50 Iout (A) 60
151
°C
600
V
2 kHz to 16 kHz in steps of factor 2
35,0
fsw = 16kHz
30,0
25,0
20,0
15,0
10,0
5,0
0,0
0
At
Tj =
DC link =
fsw from
fsw = 2kHz
10
20
30
40
50
60
Iout (A)
151
°C
600
V
2 kHz to 16 kHz in steps of factor 2
copyright Vincotech
1
Revision: 2