English
Language : 

V23990-P544-X3X-D3-19 Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
flowPIM 0
Output Inverter Application
V23990-P544-*3*-PM
600V/15A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
6
5
4
Inverter
2kHz
16kHz
3
2
1
0
60
70
80
90
At
Tj =
DC link =
Mi =
cos φ=
fsw from
125
°C
320
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
100
Th ( o C)
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
1,50 / 1,10
1
399
2
399
4
399
8
399
16
399
2,00 / 1,47
300
300
300
300
300
3,00 / 2,21
200
200
200
200
200
5,00 / 3,68
120
120
120
120
120
At
Tj =
125
°C
DC link = 320
V
Mi =
1
cos φ=
fsw from
Th =
0,8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0,85
7,50 / 5,52
0
0
0
0
0
10,00 / 7,36
0
0
0
0
0
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100
Inverter
99
2kHz
98
16kHz
97
96
95
0
1
2
3
4
5
6
At
Tj =
DC link =
Mi =
cos φ=
fsw from
125
°C
320
V
1
0,80
2 kHz to 16 kHz in steps of factor 2
7
P
8
out
(kW)
9
copyright Vincotech
3
Revision: 3