English
Language : 

V23990-P544-X3X-D3-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
flowPIM 0
Output Inverter Application
V23990-P544-*3*-PM
600V/15A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
25
20
15
Phase
Iout = f(Mi*cos φ)
Th = 60°C
Th = 100°C
Figure 6
Typical available 50Hz output current
as a function of switching frequency
25
Th = 60°C
Iout = f(fsw)
20
Th = 100°C
15
Phase
10
10
5
5
0
-1,0
-0,5
0,0
At
Tj =
DC link =
fsw =
Th from
125
°C
320
V
4
kHz
60 °C to 100 °C in steps of 5 °C
0,5
1,0
Mi*cos φ
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
Iout (A)
21,0-22,0
20,0-21,0
19,0-20,0
18,0-19,0
17,0-18,0
16,0-17,0
15,0-16,0
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
1,00
1
2
4
8
16 fsw32(kHz)64
At
Tj =
125
°C
DC link = 320
V
Th =
80
°C
0
1
10
At
Tj =
125
°C
DC link = 320
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
25
Th = 60°C
Phase
20
15
Th = 100°C
10
5
0
1
10
At
Tj =
DC link =
Th from
Mi =
125
°C
320
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 3