English
Language : 

V23990-K420-A40-P1-19 Datasheet, PDF (3/3 Pages) Vincotech – Output Inverter Application
MiniSKiiP® 3 PIM
Output Inverter Application
V23990-K420-A40-PM
preliminary datasheet
1200V/100A
Figure 9
Typical available peak output power as a function of
heatsink temperature
Pout=f(Th)
50.0
Inverter
45.0
2kHz
40.0
35.0
30.0
25.0
20.0
15.0
16kHz
10.0
5.0
0.0
60
65
70
75
80
85
90
95
Th
( o C)
100
At
Tj =
DC link =
Mi =
cos φ=
fsw from
151
°C
600
V
1
0.80
2 kHz to 16 kHz in steps of factor 2
Figure 11
Inverter
Typical available overload factor as a function of
motor power and switching frequency
Ppeak / Pnom=f(Pnom,fsw)
400
350
300
250
200
150
Motor nominal power (HP/kW)
100
7,50 / 5,52
1
665
2
625
4
554
8
441
16
297
10,00 / 7,36
498
469
415
331
222
15,00 / 11,03
332
312
277
220
148
20,00 / 14,71
249
234
208
165
111
25,00 / 18,39
199
187
166
132
0
30,00 / 22,07
166
156
138
110
0
At
Tj =
151
°C
DC link = 600
V
Mi =
1
cos φ=
fsw from
Th =
0.8
1 kHz to 16kHz in steps of factor 2
80
°C
Motor eff = 0.85
Figure 10
Typical efficiency as a function of output power
efficiency=f(Pout)
100.0
99.0
2kHz
98.0
97.0
96.0
16kHz
95.0
94.0
93.0
92.0
91.0
90.0
0.0
10.0
20.0
30.0
40.0
At
Tj =
DC link =
Mi =
cos φ=
fsw from
151
°C
600
V
1
0.80
2 kHz to 16 kHz in steps of factor 2
Inverter
50.0
60.0
Pout (kW)
copyright Vincotech
3
Revision: 1