English
Language : 

V23990-K420-A40-P1-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
MiniSKiiP® 3 PIM
Output Inverter Application
V23990-K420-A40-PM
preliminary datasheet
1200V/100A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
120
100
80
Phase
Iout = f(Mi*cos φ)
Figure 6
Typical available 50Hz output current
as a function of switching frequency
120
100
Th = 60°C
80
Iout = f(fsw)
Phase
Th = 60°C
60
60
Th = 100°C
Th = 100°C
40
40
20
20
0
-1.0
-0.8
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
0.8
Mi*cos
φ
1.0
At
Tj =
DC link =
fsw =
Th from
151
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1.00
Iout (A)
-0.80
-0.60
65.0-70.0
60.0-65.0
55.0-60.0
50.0-55.0
45.0-50.0
40.0-45.0
-0.40
-0.20
0.00
0.20
0.40
0.60
0.80
At
Tj =
151
DC link = 600
Th =
80
1
2
4
°C
V
°C
1.00
8 16 32 64
fsw
0
1
10
At
Tj =
151
°C
DC link = 600
V
Mi*cos φ = 0.8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
80
Th = 60°C
70
Phase
60
50
40
Th = 100°C
30
20
10
0
1
10
At
Tj =
DC link =
Th from
Mi =
151
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 1