English
Language : 

10-F106NIA150SA-M136F Datasheet, PDF (25/27 Pages) Vincotech – Neutral-point-Clamped inverter
10-F106NIA150SA-M136F
Switching Definitions BOOST IGBT
Figure 9
Output inverter FRED
Turn-on Switching Waveforms & definition of tQrr
(tQrr = integrating time for Qrr)
150
Id
Qrr
100
tQrr
50
%0
-50
-100
-150
3
3,1
3,2
t3i,m3 e(us) 3,4
3,5
3,6
3,7
Id (100%) =
Qrr (100%) =
tQrr =
150
A
14,35
µC
0,31
µs
Figure 10
Output inverter FRED
Turn-on Switching Waveforms & definition of tErec
(tErec= integrating time for Erec)
120
Erec
100
80
60
tEre
%
40
20
Prec
0
-20
3,05
3,15
3,25
tim3,3e5(us) 3,45
3,55
3,65
Prec (100%) =
Erec (100%) =
tErec =
52,38
kW
4,14
mJ
0,31
µs
17345020 1
8451362410205,42050 1
Measurement circuit
Figure 11
BOOST stage switching measurement circuit
Copyright by Vincotech
25
Revision: 5