English
Language : 

V23990-P589-X4X-D2-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
flow1
Output Inverter Application
V23990-P589-*4*-PM
1200V/25A
Figure 5
Typical available 50Hz output current
as a function Mi*cosφ
40
Th = 60°C
35
Phase
Iout = f(Mi*cos φ)
30
25
Th = 100°C
20
15
10
5
0
-1,5
-1,0
-0,5
0,0
0,5
At
Tj =
DC link =
fsw =
Th from
150
°C
600
V
4
kHz
60 °C to 100 °C in steps of 5 °C
1,0
1,5
Mi*cos φ
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
-0,80
Iout (A)
37,0-40,0
34,0-37,0
31,0-34,0
28,0-31,0
25,0-28,0
22,0-25,0
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
At
Tj =
150
DC link = 600
Th =
80
1
2
4
°C
V
°C
8 16 32
fsw
(kHz)
1,00
64
Figure 6
Typical available 50Hz output current
as a function of switching frequency
40
35
Iout = f(fsw)
Phase
Th = 60°C
30
25
20
Th = 100°C
15
10
5
0
1
10
At
Tj =
150
°C
DC link = 600
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
40
Phase
35
30
Th = 60°C
25
20
15
10
5
Th = 100°C
0
1
10
At
Tj =
DC link =
Th from
Mi =
150
°C
600
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2
Revision: 2