English
Language : 

V23990-P589-X4X-D2-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-P589-*4*-PM
flow1
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = -15 V
Rgon = 32 Ω
Rgoff = 32 Ω
1200V/25A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
100
IGBT
90
Mi*cosfi = 1
80
70
60
50
40
30
20
10
0
0
Mi*cosfi = -1
5
10
15
20
25
30
35
40
45
50
Iout (A)
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
60
FWD
50
Mi*cosf i= -1
40
30
20
10
Mi*cosfi = 1
0
0
5
10
15
20
25
30
35
40
45
50
Iout (A)
At
Tj =
150
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
70,0
Ploss = f(Iout)
IGBT
Figure 4
Typical average switching loss
as a function of output current
25,0
Ploss = f(Iout)
FWD
60,0
fsw = 16kHz
20,0
fsw = 16kHz
50,0
15,0
40,0
30,0
20,0
10,0
0,0
0
fsw = 2kHz
5
10
15
20
25
30
35
40
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
I4o5ut (A) 50
10,0
5,0
0,0
0
fsw = 2kHz
5
10
15
20
25
30
35
40
At
Tj =
DC link =
fsw from
150
°C
600
V
2 kHz to 16 kHz in steps of factor 2
45
50
Iout (A)
copyright Vincotech
1