English
Language : 

V23990-P543-X3X-D3-19 Datasheet, PDF (2/3 Pages) Vincotech – Output Inverter Application
flowPIM 0
Output Inverter Application
V23990-P543-*3* -PM
600V/10A
Figure 5
Phase
Typical available 50Hz output current
as a function Mi*cosφ
Iout = f(Mi*cos φ)
16
Th = 60°C
Th = 100°C
12
Figure 6
Typical available 50Hz output current
as a function of switching frequency
16
Iout = f(fsw)
Th = 60°C
Th = 100°C
12
Phase
8
8
4
4
0
-1,0
-0,8
-0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,8
1,0
Mi*cos φ
At
Tj =
DC link =
fsw =
Th from
125
°C
320
V
4
kHz
60 °C to 100 °C in steps of 5 °C
Figure 7
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
Iout = f(fsw, Mi*cos φ)
-1,00
-0,80
Iout (A)
14,0-14,5
-0,60
-0,40
13,5-14,0
13,0-13,5
12,5-13,0
12,0-12,5
-0,20
0,00
0,20
0,40
0,60
0,80
1,00
1
2
4
8 16 32 64
fsw (kHz)
At
Tj =
125
°C
DC link = 320
V
Th =
80
°C
0
1
10
At
Tj =
125
°C
DC link = 320
V
Mi*cos φ = 0,8
Th from 60 °C to 100 °C in steps of 5 °C
100
fsw (kHz)
Figure 8
Typical available 0Hz output current as a function
of switching frequency
Ioutpeak = f(fsw)
16
Th = 60°C
14
Phase
12
10
Th = 100°C
8
6
4
2
0
1
10
At
Tj =
DC link =
Th from
Mi =
125
°C
320
V
60 °C to 100 °C in steps of 5 °C
0
100
fsw (kHz)
copyright Vincotech
2