English
Language : 

V23990-P543-X3X-D3-19 Datasheet, PDF (1/3 Pages) Vincotech – Output Inverter Application
V23990-P543-*3* -PM
flowPIM 0
Output Inverter Application
General conditions
3phase SPWM
VGEon = 15 V
VGEoff = 0 V
Rgon = 32 Ω
Rgoff = 16 Ω
600V/10A
Figure 1
Typical average static loss as a function of output current
Ploss = f(Iout)
18
IGBT
Mi*cosfi = 1
15
Figure 2
Typical average static loss as a function of output current
Ploss = f(Iout)
12
Mi*cosf i= -1
10
FWD
12
8
9
6
6
4
3
0
0
4
8
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 3
Typical average switching loss
as a function of output current
6
5
4
Mi*cosfi = -1
12
16
I out (A)
IGBT
Ploss = f(Iout)
fsw = 16kHz
2
0
0
4
8
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Figure 4
Typical average switching loss
as a function of output current
2,0
1,5
Mi*cosfi = 1
12
16
I out (A)
FWD
Ploss = f(Iout)
fsw = 16kHz
3
1,0
2
1
0
0
4
8
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
12
16
I out (A)
0,5
0,0
0
4
8
At
Tj =
DC link =
fsw from
125
°C
320
V
2 kHz to 16 kHz in steps of factor 2
fsw = 2kHz
12
16
I out (A)
copyright Vincotech
1
Revision: 3