English
Language : 

10-0B066PA006SB-M992F09 Datasheet, PDF (2/3 Pages) Vincotech – Open emitter topology
flow PACK 0B
10-0B066PA006SB-M992F09
datasheet
Output Inverter Application
600 V / 6 A
figure 5.
Phase
Typical available 50Hz output current
as a function Mi*cosφ
I out = f(Mi*cos φ )
30
25
Ts = 60 °C
20
15
Ts = 100 °C
10
5
0
-1,0
-0,8
-0,6
-0,4
-0,2
0,0
0,2
0,4
0,6
0,M8 i*cos
1,0
φ
At
Tj =
125
°C
DC-link = 400
V
f sw =
T s from
4
kHz
60 °C to 100 °C in steps of 5 °C
figure 7.
Phase
Typical available 50Hz output current as a function of
Mi*cos φ and switching frequency
I out = f(f sw, Mi*cos φ )
Iout (A)
20,0-24,0
16,0-20,0
12,0-16,0
8,0-12,0
-1,00
-0,80
-0,60
-0,40
-0,20
0,00
0,20
0,40
0,60
0,80
1,00
1 2 4 8 16 32 64
At
Tj =
125
°C
DC-link = 400
V
Ts =
80
°C
f sw (kHz)
figure 6.
Typical available 50Hz output current
as a function of switching frequency I out = f(f sw)
20
Phase
18
Ts = 60 °C
16
14
12
10
Ts = 100 °C
8
6
4
2
0
1
10
At
Tj =
125
°C
DC-link = 400
V
Mi*cos φ =0,8
T s from 60 °C to 100 °C in steps of 5 °C
100
f sw (kHz)
figure 8.
Phase
Typical available 0Hz output current as a function
of switching frequency
I outpeak = f(f sw)
18
16
Ts = 60 °C
14
12
10
8
Ts = 100 °C
6
4
2
0
1
10
At
Tj =
125
°C
DC-link = 400
V
T s from 60 °C to 100 °C in steps of 5 °C
Mi =
0
100
f sw (kHz)
copyright Vincotech
2
06 Jul. 2016 / Revision 1