10-0B066PA006SB-M992F09
datasheet
flow PACK 0B
Output Inverter Application
General conditions
3phase SPWM
V GEon = 15 V
V GEoff = -15 V
R gon = 64 Ω
R goff = 64 Ω
600 V / 6 A
figure 1.
IGBT
Typical average static loss as a function of output current
P loss = f(I out)
120
Mi*cosφ = 1
100
80
60
40
20
0
0
5
10
15
20
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Mi*cosφ = -1
25
30
35
I out (A)
figure 2.
FWD
Typical average static loss as a function of output current
P loss = f(I out)
50
45
40
Mi*cosφ = -1
35
30
25
20
15
10
5
0
0
5
10
15
20
At
Tj =
125
°C
Mi*cosφ from -1 to 1 in steps of 0,2
Mi*cosφ = 1
25
30
35
I out (A)
figure 3.
Typical average switching loss
as a function of output current
18,0
IGBT
P loss = f(I out)
figure 4.
Typical average switching loss
as a function of output current
6,0
FWD
P loss = f(I out)
16,0
fsw = 16 kHz
5,0
fsw = 16 kHz
14,0
12,0
4,0
10,0
3,0
8,0
6,0
2,0
4,0
2,0
0,0
0
fsw = 2 kHz
5
10
15
20
25
At
Tj =
125
°C
DC-link = 400
V
f sw from 2 kHz to 16 kHz in steps of factor 2
30 I out (A) 35
1,0
0,0
0
fsw = 2 kHz
5
10
15
20
25
At
Tj =
125
°C
DC-link = 400
V
f sw from 2 kHz to 16 kHz in steps of factor 2
30
35
I out (A)
copyright Vincotech
1
06 Jul. 2016 / Revision 1