PI33xx-x0
PI3318-x0-LGIZ (1.8 VOUT) Electrical Characteristics
Unless otherwise specified: -55°C < TJ < 125°C, VIN =24 V, L1 = 155 nH [1]
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Input Voltage
Input Current
Input Current At Output Short
(fault condition duty cycle)
Input Quiescent Current
Input Voltage Slew Rate
VIN_DC
IIN_DC
IIN_Short
IQ_VIN
VIN_SR
Input Specifications
Minimum 1 mA load required
VIN = 24 V, TC = 25°C, IOUT =10 A
[2]
Disabled
Enabled (no load)
8
24
36
V
835
mA
20
mA
2.0
mA
2.5
mA
1
V/μs
Output Specifications
Output Voltage Total Regulation VOUT_DC [2]
Output Voltage Trim Range
VOUT_DC
[3]
Line Regulation
∆VOUT (∆VIN) @25°C, 8 V <VIN <36 V
Load Regulation
Output Voltage Ripple
Continuous Output
Current Range
∆VOUT (∆IOUT) @25°C, 0.5 A <IOUT <10 A
VOUT_AC IOUT = 5 A, COUT = 6 x 100 μF, 20 MHz BW [4]
IOUT_DC
[5]
Current Limit
IOUT_CL
1.773 1.8 1.827
V
1.4
2.0
V
0.10
%
0.10
%
25
mVp-p
10
A
12
A
Protection
VIN UVLO Start Threshold
VIN UVLO Stop Threshold
VUVLO_START
VUVLO_STOP
VIN UVLO Hysteresis
VIN OVLO Start Threshold
VIN OVLO Stop Threshold
VIN OVLO Hysteresis
VIN UVLO/OVLO Fault Delay Time
VIN UVLO/OVLO Response Time
Output Overvoltage Protection
Overtemperature
Fault Threshold
Overtemperature
Restart Hysteresis
VUVLO_HYS
VOVLO_START
VOVLO_STOP
VOVLO_HYS
tf_DLY
tf
VOVP
TOTP
TOTP_HYS
Number of the switching freq cycles
Above VOUT
7.10 7.60 8.00
V
6.80 7.25 7.60
V
0.33
V
37.0 38.4
V
36.1
V
0.77
V
128
Cycles
500
ns
20
%
130
135
140
°C
30
°C
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI33xx-x0 evaluation board with 3x4”
dimensions and 4 layer, 2 oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
[3] Output current capability may be limited and other performance may vary from electrical characteristics when switching frequency or VOUT is modified.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
Cool-Power®
Page 9 of 42
Rev 2.0
02/2016
vicorpower.com
800 927.9474