PI33xx-x0
PI3301-x0-LGIZ (3.3 VOUT) Electrical Characteristics
Unless otherwise specified: -55°C < TJ < 125°C, VIN =24 V, L1 = 200 nH [1]
Parameter
Symbol
Conditions
Min
Typ
Max
Unit
Switching Frequency
Fault Restart Delay
fS
[6]
tFR_DLY
Timing
650
kHz
30
ms
Synchronization Frequency
Range
SYNCI Threshold
∆fSYNCI
VSYNCI
Sync In (SYNCI)
Relative to set switching frequency [3]
50
110
%
2.5
V
SYNCO High
SYNCO Low
SYNCO Rise Time
SYNCO Fall Time
VSYNCO_HI
VSYNCO_LO
tSYNCO_RT
tSYNCO_FT
Sync Out (SYNCO)
Source 1 mA
Sink 1 mA
20 pF load
20 pF load
4.5
V
0.5
V
10
ns
10
ns
TRK Active Input Range
TRK Max Output Voltage
TRK Disable Threshold
Charge Current (Soft – Start)
Discharge Current (Fault)
Soft-Start Time
Soft Start And Tracking
VTRK
Internal reference tracking range
VTRK_OV
ITRK
ITRK_DIS
tSS
CTRK = 0 µF
0
1.04
V
1.2
V
20
40
60
mV
-70
-50
-30
μA
6.8
mA
2.2
ms
Enable
High Threshold
VEN_HI
0.9
1
1.1
V
Low Threshold
VEN_LO
0.7
0.8
0.9
V
Threshold Hysteresis
Enable Pull-Up Voltage
(floating, unfaulted)
VEN_HYS
VEN_PU
With positive logic EN polarity
100
200
300
mV
2
V
Enable Pull-Down Voltage
(floating, faulted)
VEN_PD With negative logic EN polarity
0
V
Source Current
IEN_SO
With positive logic EN polarity
-50
μA
Sink Current
IEN_SK
With negative logic EN polarity
50
μA
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI33xx-x0 evaluation board with 3x4”
dimensions and 4 layer, 2 oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
[3] Output current capability may be limited and other performance may vary from electrical characteristics when switching frequency or VOUT is modified.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
[7] Minimum 5 V between VIN-VOUT must be maintained or a minimum load of 1mA required.
Cool-Power®
Page 17 of 42
Rev 2.0
02/2016
vicorpower.com
800 927.9474