BCM3814B60E10A5C02 Datasheet, PDF (9/38 Pages) Vicor Corporation – Isolated, Fixed-Ratio DC-DC Converter
BCM3814x60E10A5yzz
PMBus™ Reported Characteristics
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TCASE
≤100°C (T-Grade); All other specifications are at TCASE = 25ºC unless otherwise noted.
Monitored Telemetry
• The BCM communication version is not intended to be used without a Digital Supervisor.
ATTRIBUTE
DIGITAL SUPERVISOR
PMBusTM READ COMMAND
ACCURACY
(RATED RANGE)
FUNCTIONAL
UPDATE
REPORTING RANGE RATE
REPORTED UNITS
HI Side Voltage
(88h) READ_VIN
± 5%(LL - HL)
HI Side Current
(89h) READ_IIN
± 20%(10 - 20% of FL)
± 5%(20 - 133% of FL)
LO Side Voltage[1]
(8Bh) READ_VOUT
± 5%(LL - HL)
LO Side Current
LO Side Resistance
(8Ch) READ_IOUT
(D4h) READ_ROUT
± 20%(10 - 20% of FL)
± 5%(20 - 133% of FL)
± 5%(50 - 100% of FL) at NL
± 10%(50 - 100% of FL)(LL - HL)
Temperature[2]
(8Dh) READ_TEMPERATURE_1
± 7°C(Full Range)
28V to 66V
-1A to 34A
4.7V to 11V
-6A to 204A
500u to 3000u
- 55ºC to 130ºC
100µs
VACTUAL = VREPORTED x 10-1
100µs
IACTUAL = IREPORTED x 10-2
100µs
VACTUAL = VREPORTED x 10-1
100µs
IACTUAL = IREPORTED x 10-2
100ms
RACTUAL = RREPORTED x 10-5
100ms
TACTUAL = TREPORTED
[1] Default READ LO Side Voltage returned when unit is disabled = -300V.
[2] Default READ Temperature returned when unit is disabled = -273°C.
Variable Parameter
• Factory setting of all below Thresholds and Warning limits are 100% of listed protection values.
• Variables can be written only when module is disabled either EN pulled low or VHI < VHI_UVLO-.
• Module must remain in a disabled mode for 3ms after any changes to the below variables allowing ample time to commit changes to EEPROM.
ATTRIBUTE
HI Side Overvoltage
Protection Limit
HI Side Overvoltage
Warning Limit
HI Side Undervoltage
Protection Limit
HI Side Overcurrent
Protection Limit
HI Side Overcurrent
Warning Limit
Overtemperature
Protection Limit
Overtemperature
Warning Limit
Turn on Delay
DIGITAL SUPERVISOR
PMBusTM COMMAND [3]
CONDITIONS / NOTES
(55h) VIN_OV_FAULT_LIMIT
VHI_OVLO- is automatically 3%
lower than this set point
(57h) VIN_OV_WARN_LIMIT
(D7h) DISABLE_FAULTS
Can only be disabled to a preset
default value
(5Bh) IIN_OC_FAULT_LIMIT
(5Dh) IIN_OC_WARN_LIMIT
(4Fh) OT_FAULT_LIMIT
Internal Temperature
ACCURACY
(RATED RANGE)
± 5%(LL - HL)
± 5%(LL - HL)
± 5%(LL - HL)
± 20%(10 - 20% of FL)
± 5%(20 - 133% of FL)
± 20%(10 - 20% of FL)
± 5%(20 - 133% of FL)
± 7°C(Full Range)
FUNCTIONAL
REPORTING
RANGE
DEFAULT
VALUE
28V to 66V
100%
28V to 66V
100%
28V or 66V
100%
0 to 34A
100%
0 to 34A
100%
0 to 125°C
100%
(51h) OT_WARN_LIMIT
(60h) TON_DELAY
Internal Temperature
Additional time delay to the
Undervoltage Startup Delay
± 7°C( Full Range)
± 50µs
0 to 125°C
0 to 100ms
100%
0ms
[3] Refer to internal µc datasheet for complete list of supported commands.
BCM® in a VIA Package
Page 9 of 38
Rev 1.1
05/2016