6.0 GENERAL CHARACTERISTICS
Specifications apply over all line and load conditions unless otherwise noted; Boldface specifications apply over the temperature
range of -40ºC < TJ < 125ºC (T-Grade); All Other specifications are at TJ = 25°C unless otherwise noted.
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN
TYP
MAX
UNIT
MECHANICAL
Length
Width
Height
Volume
Weight
Lead finish
THERMAL
Operating temperature
Thermal resistance
Thermal capacity
ASSEMBLY
Peak compressive force
applied to case (Z-axis)
Storage temperature
Moisture sensitivity level
ESD withstand
SOLDERING
Peak temperature during reflow
Peak time above 217°C
Peak heating rate during reflow
Peak cooling rate post reflow
SAFETY
Isolation voltage (hipot)
Isolation capacitance
Isolation resistance
MTBF
Agency approvals / standards
L
W
H
Vol
No heat sink
W
Nickel
Palladium
Gold
32.25 / [1.270]
21.75 / [0.856]
6.48 / [0.255]
0.51
0.02
0.003
32.5 / [1.280]
22.0 / [0.866]
6.73 / [0.265]
4.81 / [0.294]
15.0 / [0.53]
32.75 / [1.289]
22.25 / [0.876]
6.98 / [0.275]
2.03
0.15
0.051
mm/[in]
mm/[in]
mm/[in]
cm3/[in3]
g/[oz]
µm
V048x320y009A (T-Grade)
-40
125
°C
VTM48EF320M009A00 (M-Grade)
-55
TJ
VTM48ET320T009A00 (T-Grade)
-40
125
°C
125
°C
VTM48ET320M009A00 (M-Grade)
-55
125
°C
fJC
Isothermal heat sink and
isothermal internal PCB
1
°C/W
5
Ws/°C
TST
MSL
ESDHBM
ESDCDM
Supported by J-lead only
V048x320y009A (T-Grade)
VTM48EF320M009A00 (M-Grade)
VTM48ET320T009A00 (T-Grade)
VTM48ET320M009A00 ( M-Grade)
MSL 6, TOB = 4 hrs
MSL 5
Human Body Model,
"JEDEC JESD 22-A114-F"
Charge Device Model,
"JEDEC JESD 22-C101-D"
-40
-65
-40
-65
1000
400
6
lbs
5.41
lbs / in2
125
°C
125
°C
125
°C
125
°C
VDC
MSL 6, TOB = 4 hrs
MSL 5
245
°C
225
°C
60
90
s
1.5
3
°C/s
1.5
6
°C/s
VHIPOT
CIN_OUT
RIN_OUT
2250
Unpowered unit
2500
3200
3800
10
MIL-HDBK-217 Plus Parts Count;
25ºC Ground Benign, Stationary,
3.8
Indoors / Computer Profile
Telcordia Issue 2 - Method I Case 1;
Ground Benign, Controlled
5.6
cTUVus
cURus
"CE Marked for Low Voltage Directive and RoHS Recast Directive, as applicable"
VDC
pF
MΩ
MHrs
MHrs
VTM® Current Multiplier
Page 8 of 18
Rev 1.0
01/2014
vicorpower.com