English
Language : 

V048X320Y009A Datasheet, PDF (6/18 Pages) Vicor Corporation – High Efficiency, Sine Amplitude Converter
Not Recommended for New Designs
V048x320y009A
Efficiency & Power Dissipation 100°C Case
98
27
96
24
94
21
92
18
90
15
88
12
86
9
84
6
82
PD
3
80
0
0 1 2 3 4 5 6 7 8 9 10
Load Current (A)
VIN:
26 V
48 V
55 V
26 V
48 V
55 V
Figure 5 — Efficiency and power dissipation at 100°C
ROUT vs. TCASE at VIN = 48 V
150
126
102
78
54
30
-40
-20
0
20
40
60
Case Temperature (C)
Full Load
Figure 6 — ROUT vs. temperature
80
100
Output Voltage Ripple vs. Load
400
350
300
250
200
150
100
50
0 1 2 3 4 5 6 7 8 9 10
Load Current (A)
VIN :
26 V
48 V
55 V
Figure 7 — VRIPPLE vs. IOUT ; No external COUT. Board mounted
module, scope setting : 20 MHz analog BW
Safe Operating Area
16
14
10ms Max
12
10
8
Continuous
6
4
2
0
0 4 8 12 16 20 24 28 32 36 40
Output Voltage (V)
Figure 8 — Safe operating area
Figure 9 — Full load ripple, 100 µF CIN; No external COUT. Board
mounted module, scope setting : 20 MHz analog BW
Figure 10 — Start up from application of VIN;
VC pre-applied COUT = 100 µF
VTM® Current Multiplier
Page 6 of 18
Rev 1.0
01/2014
vicorpower.com
800 927.9474