English
Language : 

DCM3623X36G53C2YZZ Datasheet, PDF (8/25 Pages) Vicor Corporation – Isolated, Regulated DC Converter
DCM3623x36G53C2yzz
Signal Specifications
Specifications apply over all line, trim and load conditions, internal temperature TINT = 25ºC, unless otherwise noted. Boldface specifications apply over the
temperature range of -40°C < TINT < 125°C for T grade and -55°C < TINT < 125°C for M grade.
Enable: EN
• The EN pin enables and disables the DCM converter; when held low the unit will be disabled.
• The EN pin has an internal pull-up to VCC and is referenced to the -IN pin of the converter.
SIGNAL TYPE
STATE
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN NOM MAX UNIT
EN enable threshold
VENABLE-EN
2.31 V
DIGITAL
INPUT
Any
EN disable threshold
Internally generated VCC
EN internal pull up
resistance to VCC
VENABLE-DIS
VCC
RENABLE-INT
0.99
V
3.21 3.30 3.39 V
9.5 10.0 10.5 kΩ
Trim: TR
• The TR pin enables and disables trim functionality when VIN is initially applied to the DCM converter.
When Vin first crosses VIN-UVLO+, the voltage on TR determines whether or not trim is active.
• If TR is not floating at power up and has a voltage less than TR trim enable threshold, trim is active.
• If trim is active, the TR pin provides dynamic trim control with at least 30Hz of -3dB control bandwidth over the output voltage of the DCM converter.
• The TR pin has an internal pull-up to VCC and is referenced to the -IN pin of the converter.
SIGNAL TYPE
STATE
ATTRIBUTE
DIGITAL
INPUT
Startup
TR trim disable threshold
TR trim enable threshold
ANALOG
INPUT
Operational
with Trim
enabled
Internally generated VCC
TR pin functional range
VOUT referred TR
pin resolution
TR internal pull up
resistance to VCC
SYMBOL
VTRIM-DIS
VTRIM-EN
VCC
VTRIM-RANGE
CONDITIONS / NOTES
Trim disabled when TR above this threshold
at power up
Trim enabled when TR below this threshold
at power up
VOUT-RES
With VCC = 3.3 V
MIN NOM MAX UNIT
3.20 V
3.15
V
3.21 3.30 3.39 V
0.00 2.46 3.16 V
70
mV
RTRIIM-INT
9.5 10.0 10.5 kΩ
Fault: FT
• The FT pin is a Fault flag pin.
• When the module is enabled and no fault is present, the FT pin does not have current drive capability.
• Whenever the powertrain stops (due to a fault protection or disabling the module by pulling EN low), the FT pin output Vcc and provides current to drive
an external ciruit.
• When module starts up, the FT pin is pulled high to VCC during microcontroller initialization and will remain high until soft start process starts.
SIGNAL TYPE
DIGITAL
OUTPUT
STATE
Any
FT Active
ATTRIBUTE
FT internal pull up
resistance to VCC
FT voltage
FT current drive capability
FT response time
SYMBOL
RFAULT-INT
VFAULT-ACTIVE
IFAULT-ACTIVE
tFT-ACTIVE
CONDITIONS / NOTES
MIN NOM MAX UNIT
474 499 524 kΩ
At rated current drive capability
3.0
Over-load beyond the ABSOLUTE MAXIMUM
4
ratings may cause module damage
Delay from cessation of switching to
FT Pin Active
V
mA
200 µs
DCM™ DC-DC Converter
Page 8 of 25
Rev 1.1
04/2017
vicorpower.com
800 927.9474