DCM3623X36G53C2YZZ Datasheet, PDF (7/25 Pages) Vicor Corporation – Isolated, Regulated DC Converter
DCM3623x36G53C2yzz
Electrical Specifications (cont.)
Specifications apply over all line, trim and load conditions, internal temperature TINT = 25ºC, unless otherwise noted. Boldface specifications apply over the
temperature range of -40°C < TINT < 125°C for T grade and -55°C < TINT < 125°C for M grade.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Power Output Specifications (Cont.)
Output capacitance, ESR (ext.)
RCOUT-EXT At 10 kHz, excludes component tolerances
10
mΩ
Initialization delay
Output turn-on delay
tINIT
See state diagram
tON
From rising edge EN, with VIN pre-applied. See timing
diagram
25
40
ms
200
µs
Output turn-off delay
tOFF
From falling edge EN. See timing diagram
600
µs
Soft start ramp time
At full rated resistive load. Typ spec is 1-up with min
tSS
COUT-EXT. Max spec is for arrays with max COUT-EXT
120
200
ms
VOUT threshold for max
rated load current
VOUT-FL-THRESH
During startup, VOUT must achieve this threshold before
output can support full rated current
24.0
V
IOUT at startup
Monotonic soft-start threshold
voltage
IOUT-START
VOUT-MONOTONIC
Max load current at startup while VOUT
is below VOUT-FL_THRESH
Output voltage rise becomes monotonic with 25% of
preload once it crosses VOUT-MONOTONIC
0.66
A
24.0
V
Minimum required disabled duration
tOFF-MIN
This refers to the minimum time a module needs to be
in the disabled state before it will attempt to start via EN
2
ms
Minimum required disabled duration
This refers to the minimum time a module needs to be in
for predictable restart
tOFF-MONOTONIC the disabled state before it is guaranteed to exhibit
monotonic soft-start and have predictable startup timing
100
ms
Voltage deviation (transient)
%VOUT-TRANS Minimum COUT_EXT (10 ↔ 90% load step), excluding
<10
%
Settling time
tSETTLE
load line.
12.0
ms
Powertrain Protections
Input Voltage Initialization threshold
VIN-INIT
Threshold to start tINIT delay
6
V
Input Voltage Reset threshold
Input undervoltage lockout threshold
Input undervoltage recovery threshold
Input overvoltage lockout threshold
Input overvoltage recovery threshold
VIN-RESET
VIN-UVLO-
VIN-UVLO+
VIN-OVLO+
VIN-OVLO-
Latching faults will clear once VIN falls below VIN-RESET
See Timing diagram
See Timing diagram
3
10.00
36
V
17.00
V
18.00
V
45
V
V
Output overvoltage threshold
VOUT-OVP From 25% to 100% load. Latched shutdown
60.00
V
Output overvoltage threshold
VOUT-OVP-LL From 0% to 25% load. Latched shutdown
62.40
V
Minimum current limited VOUT
VOUT-UVP Over all operating steady-state line and trim conditions
17.96
V
Overtemperature threshold (internal)
TINT-OTP
125
°C
Power limit
VIN overvoltage to cessation of
powertrain switching
PLIM
tOVLO-SW
Independent of fault logic
700
W
1.5
µs
VIN overvoltage response time
tOVLO
For fault logic only
200
µs
VIN undervoltage response time
tUVLO
100
ms
Short circuit response time
Short circuit, or temperature fault
recovery time
tSC
tFAULT
Powertrain on, operational state
See Timing diagram
200
µs
1
s
DCM™ DC-DC Converter
Page 7 of 25
Rev 1.1
04/2017
vicorpower.com
800 927.9474