V110A24C400BL Datasheet, PDF (7/13 Pages) Vicor Corporation – 110V Input Maxi Family DC-DC Converter Module Features
MODULE SPECIFIC OPERATING SPECIFICATIONS
36 Vout, 400 W (e.g. V110A36C400BL)
Parameter
Min
Efficiency
88
Ripple and noise
Output OVP setpoint
40.4
Dissipation, standby
Load regulation
Load current
0
Current limit
11.3
Short circuit current
3.2
Typ
88.8
160
41.9
10.1
±0.01
12.8
12.8
Max
200
43.4
12.5
±0.2
11.11
15
15
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
36 Vout, 300 W (e.g. V110A36C300BL)
Parameter
Min
Efficiency
87
Ripple and noise
Output OVP setpoint
40.4
Dissipation, standby
Load regulation
Load current
0
Current limit
8.49
Short circuit current
5.83
Typ
89
140
41.9
7.9
±0.02
9.58
9.58
Max
Unit
%
175
mV
43.4
Volts
8.5
Watts
±0.2
%
8.33
Amps
11.3
Amps
11.3
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
48 Vout, 400 W (e.g. V110A48C400BL)
Parameter
Min
Efficiency
88.4
Ripple and noise
Output OVP setpoint
53.7
Dissipation, standby
Load regulation
Load current
0
Current limit
8.49
Short circuit current
5.83
Typ
89.9
150
55.7
11.6
±0.02
9.58
9.58
Max
Unit
%
188
mV
57.7
Volts
12.8
Watts
±0.2
%
8.33
Amps
11.3
Amps
11.3
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV
48 Vout, 300 W (e.g. V110A48C300BL)
Parameter
Min
Efficiency
86
Ripple and noise
Output OVP setpoint
53.7
Dissipation, standby
Load regulation
Load current
0
Current limit
6.37
Short circuit current
4.37
Typ
87.5
300
55.7
7.7
±0.02
7.19
7.19
Max
Unit
%
375
mV
57.7
Volts
10.5
Watts
±0.2
%
6.25
Amps
8.44
Amps
8.44
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20 MHz bandwith
25°C; recycle input voltage to restart (>100 ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250 mV