English
Language : 

V150C12C150BL_15 Datasheet, PDF (6/11 Pages) Vicor Corporation – DC-DC Converter Module
BASIC MODULE OPERATION
150 V Input
C2*
4.7nF
+IN
F1*
PC
C1*
0.2µF
PR
–IN
C3*
4.7nF
+OUT
SC
–OUT
For C1 – C5, keep leads and connections short.
Figure 1 — Basic module operation requires fusing, grounding, bypassing capacitors.
* See Maxi, Mini, Micro Design Guide.
C4*
4.7nF
C5*
4.7nF
Comprehensive Online Application Information
The Design Guide and Applications Manual includes:
• Application circuits
• Design requirements
• EMC considerations
• Current sharing in power arrays
• Thermal performance information
• Recommended soldering methods
• Accessory modules – filtering, rectification, front-ends
• Mounting options
...and more.
CLICK HERE TO VIEW
DESIGN GUIDE
Also at vicorpower.com
• PowerBench online configurators
• Over 20 Application Notes
• Online calculators – thermal, trimming, hold-up
• PDF data sheets for ALL Vicor products
150 V Micro Family
Page 6 of 11
Rev 2.8
09/2015
vicorpower.com
800 927.9474