English
Language : 

PI3318-01-LGIZ Datasheet, PDF (6/26 Pages) Vicor Corporation – 8V to 36Vin, 15A Cool-Power ZVS Buck Regulator
PI33XX-X1
PI3311-X1 (1.0 Vout) Electrical Characteristics
Specifications apply for -40C < TJ < 125C, Vin =24V, L1=85nH (Note 1) unless other conditions are noted.
Parameter
Input Specifications
Symbol
Min Typ Max Units Conditions
Input Voltage
Input Current
Input Current At Output Short
(fault condition duty cycle)
Input Quiescent Current
Input Voltage Slew Rate
Output Specifications
Output Voltage Total Regulation
Output Voltage Trim Range
Line Regulation
Load Regulation
Output Voltage Ripple
Continuous Output Current Range
Current Limit
Protection
VIN_DC
IIN_DC
IIN_Short
IQ_VIN
VIN_SR
8
24
36
V Minimum 1mA load
required
740
mA Vin = 24V, TC = 25°C,
Iout=15A
25
mA Note 2.
2
2.5
mA
Disabled
Enabled (no load)
1
V/μs Note 2.
VOUT_DC
VOUT_DC
∆VOUT(∆VIN)
∆VOUT(∆IOUT)
0.987
1.0
VOUT_AC
IOUT_DC
IOUT_CL
0.001
1.0
0.10
0.10
45
18.0
1.013
1.4
15
V Note 2.
V Note 3.
% @25°C, 8V<Vin<36V
% @25°C, 0.5A<Iout<15A
mVp-p
Iout=5A, Cout=8x100μF,
20MHz BW Note 4.
A Note 2.
A
VIN UVLO Start Threshold
VIN UVLO Stop Threshold
VIN UVLO Hysteresis
VIN OVLO Start Threshold
VIN OVLO Stop Threshold
VIN OVLO Hysteresis
VUVLO_START
VUVLO_STOP
VUVLO_HYS
VOVLO_START
VOVLO_STOP
VOVLO_HYS
VIN UVLO/OVLO Fault Delay Time
tf_DLY
VIN UVLO/OVLO Response Time
tf
Output Over Voltage Protection
VOVP
Over-Temperature Fault Threshold
Over-Temperature Restart
Hysteresis
TOTP
TOTP_HYS
Note 1: All parameters reflect regulator and inductor system
performance. Measurements were made using a standard PI33XX
evaluation board with 3x4” dimensions and 4 layer, 2oz copper.
Refer to inductor pairing table within Application Description
section for specific inductor manufacturer and value.
Note 2: Regulator is assured to meet performance specifications
by design, test correlation, characterization, and/or statistical
process control.
7.10 7.60 8.00
V
6.80 7.25 7.60
V
0.35
V
36.1 37.6
V
37.0 38.4
V
0.8
V
128
Cycles
Number of the
switching freq cycles
500
ns
20
130 135 140
% Above VOUT
°C Note 2.
30
°C
Note 3: Output current capability may be limited and other
performance may vary from noted electrical characteristics when
switching frequency or Vout is modified.
Note 4: Refer to Output Ripple plots.
Note 5: Refer to Load Current vs. Ambient Temperature curves.
Note 6: Refer to Switching Frequency vs. Load current curves.
vicorpower.com
800 735.6200
Rev 1.3
09/2015
Cool-Power®