English
Language : 

BCM384X480Y325BZZ Datasheet, PDF (6/22 Pages) Vicor Corporation – Isolated Fixed Ratio DC-DC Converter
BCM384x480y325Bzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Protection
Input overvoltage lockout threshold
Input overvoltage recovery threshold
Input overvoltage lockout hysteresis
Overvoltage lockout response time
Fault recovery time
Input undervoltage lockout
threshold
Input undervoltage recovery
threshold
Input undervoltage lockout
hysteresis
VIN_OVLO+
VIN_OVLO-
VIN_OVLO_HYST
TOVLO
TAUTO_RESTART
VIN_UVLO-
VIN_UVLO+
VIN_UVLO_HYST
Undervoltage lockout response time
Output overcurrent trip threshold
Output overcurrent response time
constant
TUVLO
IOCP
TOCP
Effective internal RC filter
Short circuit protection trip threshold
Short circuit protection response time
Thermal shutdown threshold
ISCP
TSCP
TJ_OTP
410
429
440
V
401
420
435
V
9
V
47
µs
460
540
620
ms
270
293
315
V
285
308
330
V
15
V
47
µs
7.3
11
14
A
4.0
ms
14
A
1
µs
125
°C
500
12
450
10
400
350
8
300
250
6
200
4
150
100
2
50
0
0
43.3
44.1
45.0
45.8
46.6
47.5
48.3
49.2
50.0
50.8
Output Voltage (V)
P (ave)
I (ave)
p (pk), ≤ 1ms
I (pk), ≤ 1ms
Figure 1 — Safe operating area
BCM® Bus Converter
Page 6 of 22
Rev 1.1
10/2016
vicorpower.com
800 927.9474