English
Language : 

BCM384P120T800AC1 Datasheet, PDF (6/23 Pages) Vicor Corporation – Fixed Ratio DC-DC Converter
BCM384y120x800AC1
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max Unit
Effective Output capacitance (internal)
Effective Output capacitance (external)
Array Maximum external output
capacitance
COUT_INT
COUT_EXT
COUT_AEXT
Powertrain (Cont.)
Effective value at 12 VOUT
Excessive capacitance may drive module into
SC protection
COUT_AEXT Max = N * 0.5*COUT_EXT Max
104
µF
0
1000
µF
Auto Restart Time
tAUTO_RESTART
Powertrain Protection
Startup into a persistent fault condition.
Non-Latching fault detection given VIN > VIN_UVLO+,
Module will ignore attempts to re-enable during time off
292.5
357.5 ms
Input overvoltage lockout threshold
VIN_OVLO+
430
440
450
V
Input overvoltage recovery threshold
VIN_OVLO-
420
430
440
V
Input overvoltage lockout hysteresis
VIN_OVLO_HYST
10
V
Overvoltage lockout response time
Soft-Start time
tOVLO
tSOFT-START
From powertrain active
Fast Current limit protection disabled during Soft-Start
10
µs
1
ms
Output overcurrent trip threshold
Overcurrent Response Time Constant
Short circuit protection trip threshold
Short circuit protection response time
Overtemperature shutdown threshold
IOCP
tOCP
Effective internal RC filter
ISCP
tSCP
tOTP
Temperature sensor located inside controller IC
75
85
110
A
3
ms
105
A
1
µs
125
ºC
Powertrain Supervisory Limits
Input overvoltage lockout threshold
VIN_OVLO+
420
434.5
450
V
Input overvoltage recovery threshold
VIN_OVLO-
405
424
440
V
Input overvoltage lockout hysteresis
VIN_OVLO_HYST
10.5
V
Overvoltage lockout response time
tOVLO
100
µs
Input undervoltage lockout threshold
VIN_UVLO-
195
221
250
V
Input undervoltage recovery threshold
VIN_UVLO+
225
243
255
V
Input undervoltage lockout hysteresis VIN_UVLO_HYST
15
V
Undervoltage lockout response time
Undervoltage startup delay
tUVLO
tUVLO+_DELAY
From VIN = VIN_UVLO+ to powertrain active,
EN floating, (i.e One time Startup delay from
application of VIN to VOUT)
100
µs
20
ms
Output Overcurrent Trip Threshold
IOCP
80
83
86
A
Overcurrent Response Time Constant
tOCP
2
ms
Overtemperature shutdown threshold
tOTP
Temperature sensor located inside controller IC
125
ºC
Undertemperature shutdown threshold
Undertemperature restart time
tUTP
tUTP_RESTART
Temperature sensor located inside controller IC
Startup into a persistent fault condition. Non-Latching
fault detection given VIN > VIN_UVLO+
-45
ºC
3
s
BCM® Bus Converter
Page 6 of 23
Rev 1.2
05/2015
vicorpower.com
800 927.9474