English
Language : 

PRD48AF480T400A00 Datasheet, PDF (5/9 Pages) Vicor Corporation – PRM-AL Customer Evaluation Boards
Figure 3.
PRM Customer Board Layout
switch bank
(item 5)
switch reference
(silk screen)
2.0 Hook Up
2.1 Connect the power supply +Out lead to the +In terminal of the Customer
Evaluation Board.
2.2 Connect the power supply –Out lead to the –In terminal of the Customer
Evaluation Board.
2.3 A high quality, low-noise power supply should be connected to these locations
2.4 Connect a lead between the +Out of the Customer Evaluation Board and +In
of the load.
2.5 Connect a lead between the –Out of the Customer Evaluation Board and –In
of the load.
2.6 Connections to these locations should be with short heavy gauge leads.
3.0 Verify Connections
UG:003
vicorpower.com
Applications Engineering: 800 927.9474
Page 5