English
Language : 

M-FIAM7M21 Datasheet, PDF (3/6 Pages) Vicor Corporation – Military COTS 28 Vin Filter Input Attenuator Module
SPECIFICATIONS (CONT.)
ENVIRONMENTAL QUALIFICATION
Altitude
MIL-STD-810F, Method 500.4, Procedure I & II, 40,000 ft. and 70,000 ft. Operational.
Explosive Atmosphere
MIL-STD-810F, Method 511.4, Procedure I, Operational.
Vibration
MIL-STD-810F, Method 514.5, Procedure I, Category 14, Sine and Random vibration per Table 514.5C for Helicopter AH-6J Main Rotor
with overall level of 5.6 G rms for 4 hours per axis. MIL-STD-810F, Method 514.5C, General Minimum Integrity Curve per Figure 514.5C-17
with overall level of 7.7 G rms for 1 hour per axis.
Shock
MIL-STD-810F, Method 516.5, Procedure I, Functional Shock, 40 g. MIL-S-901D, Lightweight Hammer Shock, 3 impacts/axis, 1,3,5 ft.
MIL-STD-202F, Method 213B, 60 g, 9ms half sine. MIL-STD-202F, Method 213B, 75 g, 11ms Saw Tooth Shock.
Acceleration
MIL-STD-810F, Method 513.5, Procedure II, table 513.5-II, Operational, 2-7 g, 6 directions.
Humidity
MIL-STD-810F, Method 507.4.
Solder Test
MIL-STD-202G, Method 208H, 8 hour aging.
ENVIRONMENTAL STRESS SCREENING
Parameter
Operating temperature
Storage temperature
Temperature cycling*
Ambient test @ 25°C
Power cycling burn-in
Functional and parametric ATE tests
Hi-Pot test
Visual inspection
Test data
H-Grade
-40°C to +100°C
-55°C to +125°C
12 cycles
-65°C to +100°C
Yes
12 hours, 29 cycles
-40°C and +100°C
Yes
Yes
vicorpower.com
M-Grade
-55°C to +100°C
-65°C to +125°C
12 cycles
-65°C to +100°C
Yes
24 hours, 58 cycles
-55°C and +100°C
Yes
Yes
vicorpower.com
Shut Down Time vs. Overvoltage
250
200
150
100
50
0
60 70 80 90 100 105 110 120
Vin (V)
Figure 1 – T = Time period before over-voltage protection.
Vin = Input voltage (switching up from 28 Vdc)
Figure 2 – Conducted Noise; M-FIAM7 and
MP028F036M12AL + MV036F120M010 DC-DC V•I Chip
modules operating at 28 Vdc, 120 W.
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Set your site on VICOR at vicorpower.com