English
Language : 

M-FIAM7M21 Datasheet, PDF (2/6 Pages) Vicor Corporation – Military COTS 28 Vin Filter Input Attenuator Module
SPECIFICATIONS
(typical at TBP = 25°C, nominal line and 75% load, unless otherwise specified)
INPUT SPECIFICATIONS
Parameter
Input voltage
Inrush limiting
Transient immunity
Min
Typ
Max
Unit
Notes
14
28
50
Vdc
Continuous
0.007
A/µF
100
Vdc
50 ms per MIL-STD-1275A/B/D, continuous operation
250
Vdc
70 µs per MIL-STD-1275B, continuous operation
70
Vdc
20 ms per MIL-STD-704A, continuous operation
80
Vdc
100 ms per DO-160E, Section 16, Power Input, Category Z
OUTPUT SPECIFICATIONS
Parameter
Output current
Output power
Efficiency
Internal voltage drop
External capacitance
Min
Typ
Max
Unit
Notes
10
A
Over continuous input and temp. range (see Fig.4)
130
W
Transient compliance over temp. range (see Fig.6)
96
98
%
0.5
0.7
@10 A, 100°C baseplate
See illustration C1 on page 4
330
1000
µF
63 V
CONTROL PIN SPECIFICATIONS
Parameter
ON/OFF control
Enable (ON)
Disable (OFF)
Min
Typ
Max
Unit
Notes
0.0
1.0
Vdc
Referenced to – Vout
4.0
5.50
Vdc
100 kΩ internal pull-up resistor
SAFETY SPECIFICATIONS
Parameter
Dielectric withstand
Min
Typ
Max
Unit
Notes
1,500
Vrms
Input/Output to Base
2,121
Vdc
Input/Output to Base
EMI
Standard
MIL-STD-461E
Conducted emissions:
Conducted susceptibility:
Test Procedure
CE101, CE102
CS101, CS114, CS115, CS116
Notes
GENERAL SPECIFICATIONS
Parameter
Min
Weight
Warranty
Typ
Max
Unit
Notes
3.3 (94) Ounces (grams)
2
Years
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715
M-FIAM7
Rev. 2.4
Set your site on VICOR at vicorpower.com
Page 2 of 6