English
Language : 

LOPAC Datasheet, PDF (3/8 Pages) Vicor Corporation – PFC Mini, PFC Micro, PFC MicroS Power Factor Corrected, AC-DC Switchers
Performance Specifications
The following are typical performance specifications at room
ambient temperature, nominal line voltage (115/230Vac) and
75% load on all outputs, unless specified otherwise. For detail
specifications, consult the Design Guide for the LoPAC
configuration of interest. This is available from any sales office
(see Back Cover) or our web site (vicorpower.com).
INPUT CHARACTERISTICS
Parameter
PFC Mini
AC Input
Voltage
Frequency
DC Input
100-380
Line Regulation
Inrush Current
@ 115Vac
30
@ 230Vac
60
Ride Through Time
@ load
1,200
Conducted EMI/RFI
FCC Class A
EN55022 Class A
Power Factor
Harmonic Current Limits
Surge Immunity
Dielectric Withstand
Primary to Chassis GND
Primary to Secondary
Secondary to Chassis GND
PFC Micro
PFC MicroS
Units Notes
85-264
47-500
0.4
100-300
Vac
Hz
Vdc
%
From low line to high line
5
10
>20
500
FCC Class A
EN55022 Class A (consult factory)
>0.98
EN61000-3-2/A14
IEC61000-4-5
A rms
A rms
ms
W
PFC Mini with 1st Gen units
meets FCC & EN Class B
>75% load
Class A
Level 3 Performance Criteria B
2,121
Vdc
4,242
Vdc
750
Vdc
OUTPUT CHARACTERISTICS
Parameter
PFC Mini
Setpoint Accuracy
Load Regulation
Temperature Regulation
Long Term Drift
Output Ripple & Noise
≤10Vout
>10Vout
Voltage Trim Range
1st Gen Slots
2nd Gen Slots
Remote Sense Compensation
OVP Set Point
Current Limit
PFC Micro
0.5
0.05
0.2
0.005
0.02
100
1.0
50-110
10-110
0.5
125
115
PFC MicroS
Units
%
%
%
%/°C
%/khr
Notes
of Vnom
10% to full load
No load to full load
-20º to +65ºC
mV 20 MHz bandwidth
% Vout 20 MHz bandwidth
% Vout
% Vout
Vdc
% Vout
% Imax
±10% on 10-15 Vout
Preload may be required
Autosense (See page 2)
Not available on 1st Gen Minis
Auto recovery
ENVIRONMENTAL CHARACTERISTICS
Parameter
PFC Mini
Storage Temperature
Operating Temperature
Full Rated Power
50% Rated Power
Safety Approvals
PFC Micro
-40 to +85
PFC MicroS
-20 to +45
-20 to +65
UL, CUL, TÜV, VDE, CE Marked
Units Notes
°C
°C
°C
MECHANICAL CHARACTERISTICS
Parameter
PFC Mini
Weight
5.5
2,5
Overall Dimensions
12.20 x 6.00 x 1.75
309,9 x 152,4 x 44,5
PFC Micro
5.2
2,4
10.40 x 5.06 x 1.86
264,1 x 128,5 x 47,3
PFC MicroS
3.1
1,4
7.95 x 5.06 x 1.86
201,9 x 128,5 x 47,3
Units
lbs
kg
in
mm
Notes
LxWxH
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 LoPAC Family
Set your site on VICOR at www.vicorpower.com
Rev. 1.2
Page 3 of 8