English
Language : 

LOPAC Datasheet, PDF (2/8 Pages) Vicor Corporation – PFC Mini, PFC Micro, PFC MicroS Power Factor Corrected, AC-DC Switchers
DC Output Selections
The versatility of the LoPAC series is due, in large part, to the
wide array of Vicor modules available to be configured into the
different package formats. Slots can be populated with 1st or
2nd Generation modules in full, half or quarter brick sizes.
Vicor’s full VI-26x, VI-J6x and V375 standard product
matrices are available to choose from. In addition, the full range
of non-standard voltages and powers from 1 to 100Vdc and 10
to 600W is also available for inclusion. The table below is just a
sampling of some of the most popular standard outputs that can
be configured into LoPAC slots.
Output
Voltage
2Vdc
3.3Vdc
5Vdc
12Vdc
15Vdc
24Vdc
28Vdc
48Vdc
2nd Gen
160
264
400
600
600
600
600
600
Available Power (W) per Package Size
Maxi
1st Gen
80
60
132
99
200
150
200
150
200
150
200
150
200
150
200
150
2nd Gen
100
150
200
300
300
300
300
300
Mini
1st Gen
40
30
66
50
100
75
100
75
100
75
100
75
100
75
100
75
Micro
2nd Gen
50
75
100
150
150
150
150
150
LoPAC Slot Configurations
The DC-DC converter modules are used to populate each
LoPAC converter slot. Each slot can be configured in different
ways depending on module sizes and power limitations.
The following table summarizes the available slot
configurations for each of the three LoPAC packages.
Model
Type
PFC Mini
PFC Micro
PFC MicroS
# Slots
3
2
1
Maximum Output Power
Total
per
@ 230Vac @ 115Vac
Slot
1,500W
800W
500W
800W
500W
600W
600W
500W
600W
Modules per Slot
1 Maxi or 2 Minis
1 Maxi or 2 Minis or 3 Micros
1 Maxi or 2 Minis or 3 Micros
Autosense Feature*
This is a new feature implemented in all converter slots in the
LoPAC family. If remote sense connections are not needed or
are inadvertently not made, no local sense connections are
necessary. Simply connect the output(s) to the load and the
*Applies to converter slots utilizing Maxi or Mini size converters.
Part Numbering
converter(s) will automatically operate in the local sense mode.
If remote sense connections are made, the unit will operate in
remote sense mode.
PM
Product Prefix
PM PFC Mini
PC PFC Micro
PS PFC MicroS
X1
Number of
Output
Voltages
- X2
X3
Number of
1st Gen module(s)
Number of
2nd Gen module(s)
XXX
Factory
Assigned
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 Westcor Division 408-522-5280 LoPAC Family